AudiologyOnline Phone: 800-753-2160


Exam Preview

Working with Connexx First Installment

View Course Details Please note: exam questions are subject to change.


1.  Which of these tabs are visible in both the expanded and collapsed mode in First Fit:
  1. Acoustical Parameters
  2. Critical Gain
  3. Fitting Formula
  4. All of the above
  5. None of the above
2.  Which of the following parameters may be modified in Basic Tuning?
  1. Soft Sounds
  2. Loud Sounds
  3. Own Voice
  4. Speech
  5. All of the above
3.  Which of these controls can be used to reduce the gain above 1,200 HZ and increase the gain below 1,200 Hz, simultaneously?
  1. Soft Sounds
  2. Too sharp
  3. Too muffled
  4. All of the above
  5. None of the above
4.  Which of the following control areas may be found in Fine Tuning:
  1. Amplification settings
  2. Noise reduction / Microphone
  3. Bandwidth Features
  4. All of the above
  5. None of the above
5.  Which of these is not a function of the Input mode control area?
  1. It allows to change the input mode from microphone to telecoil in the Automatic memory (Program 1)
  2. It allows to combine the BluRCU / Mini Blu RCU and the microphone in a BT-Transmitter memory
  3. It allows to combine the Telecoil and the microphone in a BT-Transmitter memory
  4. All of the above
  5. None of the above
6.  Where would you go to activate the feature that allows you to move output from frequencies where it would not be beneficial to provide amplification, to areas where it would be?
  1. Bandwidth Features
  2. Input Mode
  3. Amplification Settings
  4. Noise Reduction / Microphone
7.  The Loudness Control tab allows you to change:
  1. Gain and compression simultaneously
  2. Gain only
  3. Compression only
  4. Crossover frequencies
8.  The function that allows you to control the gain for three levels of input (Soft Sounds, Mid Sounds, and Loud Sounds is:
  1. The Maximum Power Output (MPO)
  2. The Level Dependent Controls
  3. The Frequency Details
  4. None of the above
9.  Which of these criteria must be met to make the Bandwidth Compression system activate automatically:
  1. Difference of 50 dB between contiguous octaves
  2. High frequency thresholds of 80 dB or more
  3. Use double domes in RIC and open fit BTEs
  4. All of the above
  5. None of the above
10.  A value of 1.00 in a compression channel means:
  1. That the affected channel has maximum compression at the selected kneepoint.
  2. That the affected channel is completely linear.
  3. That the Maximum Power Output has been reduced to the minimum
  4. All of the above
  5. None of the above

Our site uses cookies to improve your experience. By using our site, you agree to our Privacy Policy.